Compression Fittings Technical Information
Robert-James Sales, Inc.
 
 
Compression Fittings
Loading
   Compression Fittings Menu    Technical Information

Technical Information
Sec. A
• How to order

Sec. B
• Instrument Tee
• Heat Exchanger Tee
• Thermocouple Bore Through
• TylubeTM Thread Lubricant

Sec. C
• CBC-Lok® Installation Instructions
• To Remove Tube and Re-Connect Tube Fitting

Sec. D
• CBC-Lok® Tubing Selection & Preparation

Sec. E
• Gas Service
• Precautions for Weld Ends
• Typsy Leak Detector
• Gap Gages
• Safety Guidelines
• Quality Control

Sec. F
• Pipe Thread Specifications
• Temperature Ratings
• Tube Pressure Derating Factors at Elevated Temperatures

Sec. G
• Heat Traceability
• Raw Material Specifications
• Tylok Pre-Setting Tool

Sec. H
• Tube Insertion Chart
• Tubing–General Applications

Sec. I  
• Notice
• Limited Warranty

Pipe Thread Specifications

Tylok Pipe Fittings are manufactured from materials meeting applicable ASTM or ASME specifications, with pipe threads which meet or exceed ANSI B1.20.1 requirements. Strict quality control procedures are followed
throughout production. All parts are individually inspected to provide the finest possible product.

Materials: Brass | 316 Stainless Steel

These charts are to be used as a guide only and are based on normal wall thicknesses, used for the various sizes. These ratings may vary widely from effects such as the proper use of sealants, size of stock, temperature, corrosion factors, etc. Therefore, Tylok International, Inc., assumes no responsibility for its accuracy in any individual design.


Temperature Ratings

Tylok Instrumentation Fittings are rated at the following temperatures:

316 Stainless -325°F to 1200°F (-198°C to 648°C)

Brass -40°F to 400°F (-40°C to 204°C)

Note: Consideration should be given to maximum temperature ratings if fittings and/or tubing are coated or plated.


Tube Pressure Derating Factors at Elevated Temperatures

The following table lists derating factors that must be considered in applications above that of ambient temperatures.


These charts are to be used as a guide only and are based on normal wall thicknesses, used for the various sizes. These ratings may vary widely from effects such as the proper use of sealants, size of stock, temperature, corrosion factors, etc. Therefore, Tylok International, Inc., assumes no responsibility for its accuracy in any individual design.
Example
Type 316 Stainless Steel 1/4” O.D. x .049” wall at
800°F is…

7,500 PSI x .80 = 6,000 PSI

Therefore, the suggested allowable working pressure for 316 Stainless Steel - 1/4” O.D. with .049” tube wall - at 800°F is 6,000 PSI.